Speaker

Dec 12-13, 2022    New York, USA
4th International Conference on

Cardiology and Cardiovascular Medicine

Veysel zgr Bar

Veysel zgr Bar

Ankara University Turkey

Title: Comparison of two different types of stent platforms with biolimus eluting : 3-year Randomized, Prospective, Single center, Clinical and Angiographic trial

Abstract:

Aim: Biolimus eluting stents (BES) are the most popular stent technologies with biodegradable polymer in interventional cardiology. Many studies showed that restenosis rates were lower in BES than in other drug-eluting stents. Many different forms of BES are commercial now, but there isn’t any clinical trial that comparison of these platforms. This study is the first study that compares biolimus eluting stents with rigid metallic and flexible metallic platforms.
Methods: This trial is randomized, open-label, prospective, uncentered in Ankara Turkey. 481 patients presenting with stable coronary disease or acute coronary syndromes undergoing BES implantation in de novo native-vessel coronary lesions were randomly assigned to treatment with flex metallic stent platform BES (BES flex; n =120) or right metallic stent platform BES (BES right n:361) and underwent clinical follow-up or angiographically control to 3 years (Figure 1). The primary endpoint was death from any cause. The secondary endpoints were death from a cardiovascular cause, myocardial infarction, target lesion revascularization, and definite in-stent restenosis. 
Results: All of 481 randomized patients were analysed (Table 1). The primary end-point, death from all causes, was similar in both groups (BES-flex: 2.2% vs BES-rigid 2%; p: 0.74). The secondary endpoints, cardiac death (BSS-flex: 1.7% vs BSS-rigid 1.7%; p: 0.99), myocardial infarction (BSS-flex: 6% vs BSS-rigid 7%; p: 0 , 52), target vessel revascularization (BSS-flex: 15% vs BSS-rigid 16%; p: 0.63) were similar in both groups. Coronary angiography control was performed in 142 patients and angiographic restenosis rate was similar in both groups (BSS-flex 19.4% vs BSS-rigid 21.7%, p = 0.775) (Table 2).

Conclusion: BES rigid stents have the same efficacy and safety compared to BES flex stents, whose efficacy and safety have been proven in large studies. With this result, the use of BES rigid stents can provide the same effectiveness at a lower cost. This study is the first clinical study to compare BES with different metallic stent platforms.

Biography:

Veysel Özgür Barış has completed his cardiology fellowship at the age of 28 from Ankara University and his physiology Ph.D. at the age of 34 years from Hacettepe University. He has published more than 10 papers in reputed journals and has been serving as an editorial board member of repute.